Simulators of mammary pathologies enclosed on a breast phantom for image quality control in mammography

Authors

  • Ivânia Ferreira Souza Hospital das Clínicas, UFMG.
  • Luciana Batista Nogueira Departamento de Anatomia e Imagem, Faculdade de Medicina, UFMG
  • Tarcísio Passos Ribeiro Campos Departamento de Engenharia Nuclear; UFMG.

DOI:

https://doi.org/10.14808/sci.plena.2016.016001

Keywords:

breast phantom, mammary pathologies, image quality control

Abstract

This paper addresses the development of simulator of breast pathologies for image quality control in mammography. Simulators of neo density´s objects had been used for reproducing the breast pathologies. These objects had been adhered between two dental wax plates, inserted in an anthropomorphic and anthropometric compressed breast (AACB) phantom and submitted to radiological expositions. The AACB phantom is constituted of glandular, adipose and skin equivalent tissues, representing a fibro adipose breast with 50% of glandular and 50% adipose tissues. Radiographies of the AACB breast phantom were taken in the conventional and computerized systems. Two standard commercial breast phantoms referenced by the Brazilian College of Radiology and by the American College of Radiology were used as validation. After the expositions, qualitative image evaluation were carried through, identifying how many objects of the pathologies had been depicted, following the norms of quality control demanded by the Brazilian control agencies. The quality control measurements related to the pathology´s identifications, comparing with the standard breast phantoms, provided similar values. The simulating objects of mammary pathologies enclosed on the AACB phantom provide a suitable system for image quality control in mammography. 

Author Biographies

Luciana Batista Nogueira, Departamento de Anatomia e Imagem, Faculdade de Medicina, UFMG

http://lattes.cnpq.br/3084251272040826

Tarcísio Passos Ribeiro Campos, Departamento de Engenharia Nuclear; UFMG.

Área: Ciência das Radiações

http://lattes.cnpq.br/2004647037137301


Downloads

Published

2016-01-19

How to Cite

Souza, I. F., Nogueira, L. B., & Campos, T. P. R. (2016). Simulators of mammary pathologies enclosed on a breast phantom for image quality control in mammography. Scientia Plena, 12(1). https://doi.org/10.14808/sci.plena.2016.016001

Similar Articles

<< < 6 7 8 9 10 11 12 13 14 > >> 

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)